Heatban

We have higher density to meet requirement.

CHARACTERISTIC OF HEATBAN

  • Density: it can be manufactured within the range of 30 – 45 kg/m3.
  • Board size: 600 x 1250 mm. or any other size on length, as per inquiry.
  • Thickness: 25, 30, 40, 50, 60, 70, 75, 100 mm.
  • Edges: Rebated edges or straight.
  • Offers high resistance to heat flow.
  • The waterproofing membrane is protected from extreme thermal Stress and from the various effects of the weather. Possess closed and uniform cell structure.
  • The inverted roof system reduces maintenance cost of the roof.
  • Long term efficient insulation capability.
  • High compressive strength.
  • Long term high insulation.
  • High resistance to water absorption.
  • Insulation saves energy and money.
  • ideal insulation for high load bearing floors such as those found in
    Cold stores, warehouses and parking areas.

ROOF APPLICATION

1. Insulation with Top Layer Gravel protection.

  1. Gravel layer.
  2. Separation layer.
  3. Heatban.
  4. Waterproofing membrane.
  5. Screed to fall.
  6. Roof deck.

1. Insulation with Top Layer Gravel protection.

  1. Gravel layer.
  2. Separation layer.
  3. Heatban.
  4. Waterproofing membrane.
  5. Screed to fall.
  6. Roof deck.

1. Insulation with Top Layer Gravel protection.

  1. Gravel layer.
  2. Separation layer.
  3. Heatban.
  4. Waterproofing membrane.
  5. Screed to fall.
  6. Roof deck.

WALL APPLICATION

INTERNAL WALL INSULATION

EXTERNAL WALL INSULATION

CAVITY WALL INSULATION

FLOOR APPLICATION

CHARACTERISTICS OF FLOORBAN

  • High compressive strength.
  • Long term high insulation.
  • High resistance to water absorption.
  • Insulation saves energy and money.
  • Density: 38-45 Kg/m3
  • Board size: 1250 × 600 mm
  • Thickness: 25, 30, 40, 50, 60, 70, 75, 100 mm
  • Edges: Rebated edges or straight.

FLOORBAN BOARDS CAN BE USED AS A WORKING SLAB

  1. Flooring screed or boarding
  2. Separating / slip layer
  3. Heatban.
  4. Concrete floor slab
  5. Damp proof membrane (under slab position shown)
  6. Sand blinding
  7. Hardcore
  8. Wall lining & skirting
  9. Existing external wall
  10. Insulation strip at screed perimeter
  11. DPC

TECHNICAL DETAILS

PROPERTIES TEST METHOD UNIT ROOFBAN
Three main categories of Heatban THERMAL INSULATION BOARDS
Density ASTM D1622 kg/m³ 30-32 32-35 38-45
Thermal Conductivity @ 24˚C mean temperature ASTM C518 W/mk
Btu-in/hft²˚F
0.03
0.21
0.028
0.2
0.026 – 0.027
0.18 – 0.19
Compressive Strength @ 10% Deflection ASTM D1621 kPa 320 – 350 400 – 450 500 – 700
Water Absorption by Submersion ASTM C272 % by Volume ≤1 ≤1 ≤1
Water Vapor Permeability ASTM E96-00 Perm-inch 0.6 – 0.8 0.5 – 0.7 0.7
Dimensional Stability ASTM D2126 % Change <0.2 <0.2 <0.2
Flexural Strength ASTM C203 kPa 380 – 400 400 – 425 510 – 525
Fire Classification (Exova – Germany) UL 732 Building Mat Class A class A class A class
Underwriters Laboratory -UL 723 = ASTM E-84 Standard test method for surface burning characteristics of Building materials under code ASTM C 578-13 UL-723 =
ASTM E – 84
Fire spread +
smoke developed index
10 – 25
65 – 120
10 – 25
65 – 120
10 – 25
65 – 120
Heatban warranty 10 years Limited Warranty for Heatban insulation in a protected membrane roof assembly
Available Sizes of the xps sheets Width 600mm Length 1250 mm & Length 2500 mm(optional)
Thickness 25mm, 30mm, 40mm, 50mm, 60mm, 70mm, 75mm, 100mm
Edge Profile Ship Lap Edge
UV light All polystyrene-based products slowly deteriorate if exposed to UV light (sunlight) for long periods of time. ARNON Plastic Industries recommends coveringHeatban® extruded polystyrene (XPS) rigid insulation as soon as possible followingInstallation, due to the potential for damage from ultra-violet light (UV). If Heatban® insulation is not covered immediately, it is recommended that it be covered within 60 days. When exposed for up to 60 days, gradual colour fading and/or dusting of the surface may occur. Fading or colour loss, while noticeable, will not affect the performance of Heatban® XPS insulation boards.